In your CLOCKxx member, did you specify the SIMETRID parameter?  Each member
of a sysplex must use the same SIMETRID number.  Usually all members of a
sysplex use the same CLOCKxx member.

On Mon, 22 Jan 2007 11:29:15 -0600, Len Rugen <[EMAIL PROTECTED]> wrote:

>I'm trying to add my 2nd lpar to a sysples, but I'm getting message
>
>IXC414I CANNOT JOIN SUSPLEX PRODPLEX WHICH IS RUNNING IN MONOPLEX MODE:
EXTERNAL TIME REFERENCE IS IN LOCAL MODE
>
>The system that is active has PLEXCFG=MULTISYSTEM in IEASYS and at IPL said:
>
>IXC418I SYSTEM PROD IS NOW ACTIVE IN SYSPLEX PRODPLEX
>
>What am I missing?  
>
>
>Len Rugen

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html