In your CLOCKxx member, did you specify the SIMETRID parameter? Each member of a sysplex must use the same SIMETRID number. Usually all members of a sysplex use the same CLOCKxx member.
On Mon, 22 Jan 2007 11:29:15 -0600, Len Rugen <[EMAIL PROTECTED]> wrote: >I'm trying to add my 2nd lpar to a sysples, but I'm getting message > >IXC414I CANNOT JOIN SUSPLEX PRODPLEX WHICH IS RUNNING IN MONOPLEX MODE: EXTERNAL TIME REFERENCE IS IN LOCAL MODE > >The system that is active has PLEXCFG=MULTISYSTEM in IEASYS and at IPL said: > >IXC418I SYSTEM PROD IS NOW ACTIVE IN SYSPLEX PRODPLEX > >What am I missing? > > >Len Rugen ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html