PRIVAT means it wants a scratch tape. The "-1" is really part of the
next line.
Eg "- 1 OFFLINE, NOT ACCESSABLE 0593" is really one message.

What is the UNITNAME in HSM set up like? Does it only include device
0593? That would be my first guess.


SETSYS
 UNITNAME(TAPELIB5)

In HCD TAPELIB5 is defined as 590,4

Now that I put all tape online I get the following.
F HSM,RECYCLE ML2    EXECUTE
ARC0830I RECYCLE COMMAND PROCESSING STARTING
ARC0845I CONNECTED SET BEGINNING WITH VOLUME ML1010 529
ARC0845I (CONT.) NOT  RECYCLED. RC=0004.
ARC0834I RECYCLE TASK 0001 ENDING. RC=0004, REAS=0000
ARC0831I RECYCLE COMMAND PROCESSING ENDING
--
Mark Pace
Mainline Information Systems

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to