We are z/OS V1R7.  I am sharing SYS1.PARMLIB between two LPAR's. One
LPAR needs more OMVS parms then the other. I thought I would used the
SYSPARM parameter of the LOAD or IEASYMxx member. This would be where I
would specify the OMVS statement. When I did the IPL the SYSPARM was
ignored. It says the SYSPARM will be ignored if you specify A,P, S, or T
IMSI character, which I specify T. If I change to use another IMSI
character lets say M then the SYSPARM should be picked up. My only
question is that I have specified IMSI character T so I would have a
chance to specify CLPA is needed, but I would not have a chance to
specify this if I don't specify T. I could put CLPA in IEASYS00, but I
may not want to do a CLPA every time I IPL. I don't want to specify a
different parmlib concatentation. Any other suggestion? 
 
Thank You  

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to