We are forced to aggregate disparate sysplexes into one sysplex. (Don't ask.)

We have a problem with system automation subplexing. The automation managers 
join two different groups, and via 'subplexing' only one of those groups' name 
can be changed (that name is ingxsg01 or 02 or whatever is specified as 
groupid). There is a second group named INGPX$$$ that is joined by only the 
HSAMs of both subplexes, not by the automation agents. Unfortunately, it is 
probably this connection that sends messages from one subplex to the other 
(where they really don't belong). 

Does anyone have an idea if it is possible to get the HSAMs not to do this? 
Definitely not send the messages but basically not join the same group. 

When I opened an ETR for this problem, IBM asked me why *I* had defined the 
INGPX$$$ group, which I certainly didn't. It will take a while until I find 
someone within IBM who even understands what I am talking about, so I thought 
I'd ask here. (I know there is a yahoo autmation group, but I find  yahoo too 
nosy in the registration process.)

Regards, Barbara Nitz
-- 