I would first go to the other LPAR and issue the D XCF,COUPLE and make sure that you don't have the same alternate defined on both systems.
Wayne Driscoll Product Developer JME Software LLC NOTE: All opinions are strictly my own. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Robert Pelletier Sent: Friday, August 24, 2007 12:32 PM To: [email protected] Subject: Re: Couple Member HELP Looking good thanks except: 13.25.12 IXC260I ALTERNATE COUPLE DATA SET REQUEST FROM SYSTEM PROD FOR WLM IS NOW BEING PROCESSED. DATA SET: SYS1.PROD.WLM.CDS02 13.25.12 *IXC248E COUPLE DATA SET SYS1.PROD.WLM.CDS02 ON VOLSER TECH02 FOR WLM MAY BE IN USE BY ANOTHER SYSPLEX. 13.25.12 *18 IXC247D REPLY U TO ACCEPT USE OR D TO DENY USE OF THE COUPLE DATA SET FOR WLM. I have 2 LPARS and they have unique datasets. I assume I can respond U? Have a Nice Day ! Bob Pelletier Connecticut Student Loan Foundation Rocky Hill, Ct. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html