You really do not need a CFL engine.  A regular CP will work.  And I am sure
you can now set the CF up to utilize the CP only when it has work to do. 
This is the way I run my CF, but I have not tried the dynamic CP usage part yet.

For a basic sysplex, all you really need are the PATHIN and PATHOUT
definitions on each LPAR which can utilize your existing CTC device
definitions.  I would not use the same ones VTAM are using.  GRS will
automatically switch to the sysplex paths.

On Fri, 14 Dec 2007 12:48:14 -0600, Staller, Allan <[EMAIL PROTECTED]>
wrote:

><snip>
>What I really would like to know is what will I be missing in the basic
>sysplex that exists in the parallel sysplex.
></snip>
>
>GRS Star
>Enhanced Catalog Sharing
>
>Probably others I can't recall off hand...
>
>HTH,

----------------------------------------------------------------------