Thanks Dean, you right.
But some option without changes in parmlib?

2008/2/14, Dean Montevago <[EMAIL PROTECTED]>:
>
> In the JES2 startup deck:
>
> INIT(1)  NAME=1,
>          CLASS=??,
>          START=NO
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
> Behalf Of Angel Tamayo
> Sent: Thursday, February 14, 2008 3:05 PM
> To: IBM-MAIN@bama.ua.edu
> Subject: JES2 startup question
>
>
> Hi,
> Customer had requested to start JES2 with all INITs drained, in order to
> prevent that batch jobs start running on INITs after the IPL and before
> batch processing application is fully up.
>
> What options do I have?
>
>
> ----------------------------------------------------------------------