I have questions regarding OSA Express3 1000Base-T, FC3367. There are 4 copper ports per card.
Q1: How many CHPids has the card? 2/4 ? Answer: 2 Q2: (assuming 2 chpids per card) In such case I have to define both ports per chpid as same type. For example I must have a *pair* of ICC ports, pair of OSE ports, etc. T/F? Answer: Yes. CHPID type have to remain the same since there is only one CHPID. When defined as OSC only one port is usable (Port 1 is set to disable). When defined OSD you need to address individual port names on the TRLE with PORTNUM=0/1 when undefined default is 0. Q3. Any other "gotchas"? Answer: Not that i know of. thanks HTH Natarajan NOTICE OF CONFIDENTIALITY The information contained in this communication, including but not limited to any accompanying document(s) and/or attachment(s), is privileged and confidential and is intended solely for the above-named individual(s). If you are not the intended recipient, please be advised that any distribution, copying, disclosure, and/or use of the information contained herein is strictly prohibited. If you received this communication in error, please destroy all copies of the communication, whether in electronic or hard copy format, and immediately contact the Security Office at EDFUND at (916) 526-7539 or [email protected]. Thank you. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html