Hi John,

Yes, I did notice that.

Checking the jcl the first reference to the dataset in question is

//M4OLD  DD  DSN=HLQ.PUBLIC.MASTER,DISP=(OLD,PASS,CATLG),  
//       UNIT=ETAPE,EXPDT=99000   

The second reference is a Icegener

//COPY.SYSUT2  DD  DSN=HLQ.PUBLIC.MASTER,DISP=(OLD,KEEP)  

One would think Expdt=99000 should have been coded here but that is not the 
case.
                            
Dave O'Brien
NIH Contractor
________________________________________
From: IBM Mainframe Discussion List [ibm-m...@bama.ua.edu] On Behalf Of John 
Kelly [john_j_ke...@ao.uscourts.gov]
Sent: Tuesday, June 02, 2009 5:50 PM
To: IBM-MAIN@bama.ua.edu
Subject: Re: Question concerning pre-mature uncatalog/delete of a tape file.

Hi Dave,

I'm sure that you noticed but the CRTDT changed with RGWOPMSC @ 2009142
20.18.36.15. It went from
CRTDT=09135 EXPDT=99000 at 20.18.01.43 to CRTDT=09142 EXPDT=00000 at
20.18.36.15. And it looks like the same job? I don't know how to read DAF
but could a step in the job (SYSUT2) opened the tape for output and
changed TMS?
Just a thought

Jack Kelly
202-502-2390 (Office)

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to