Or, the exit is not invoked APF authorized.  The AC(1) specification for
the load module only applies to the executed (job step) program.  Not to
just any program that is invoked.

Chuck Arney
illustro Systems International, LLC
http://www.illustro.com
Internet-enable your applications with z/Ware V2
Voice: 214-800-8900 X#5562
--
This e-mail is private and may be confidential and is for the intended
recipient only. If misdirected, please notify us by telephone and
confirm that it has been deleted from your system and any copies
destroyed. If you are not the intended recipient you are strictly
prohibited from using, printing, copying, distributing or disseminating
this e-mail or any information contained in it.  
  
We use reasonable measures to virus scan all E-mails leaving illustro
but no warranty is given that this E-mail and any attachments are virus
free. You should ensure you have adequate measures in place for your own
virus checking.

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
> Behalf Of John Kelly
> Sent: Friday, June 19, 2009 4:24 PM
> To: IBM-MAIN@bama.ua.edu
> Subject: Re: Storage
> 
> <snip>
> Why do I get the 047 abend?
> <unsnip>
> 
> if you're sure that the lib is the running system's APF list (like
from
> ISRDDN APF) the it's usually a STEPLIB that contains an unauthorized
> library.

----------------------------------------------------------------------