Not always,  Here is the ABEND 306-30 documentation.

The user attempted to use a controlled program but is not 
authorized by RACF to use that program. This can occur when a 
user has EXECUTE access to a program library's data set profile,
even if none of the program modules involved are RACF program 
protected. Have the system security administrator grant you READ
access to the data set profile instead. 
 
 
 
 
 
Thanks,
 
Craig
 
 
 



From:   Scott Ford <scott_j_f...@yahoo.com>
To:     IBM-MAIN@LISTSERV.UA.EDU
Date:   07/06/2012 15:34
Subject:        RACF question
Sent by:        IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU>



All,
I have a question, I have a customer receiving a csv0025i abends306-30 on 
a adduser.
Shouldn't we be seeing a ich408i message ?

Scott ford