W dniu 2012-10-02 10:37, Hunkeler Peter (KIUP 4) pisze:
(3) The CPU chip makers are about to apply Mobile technology to
their Server CPU's.  Mobile CPU's dynamically adjust their clock
speeds to fit the workload, sometimes running at 200MHz and at
other times running full throttle at 2GHz+ or more.  Server CPU's
will soon do the same.  When throttled down, a CPU uses much less
energy and radiates much less heat.

Is there any model of z that does this yet?

MVS puts CPs into a (restartable) wait state when there is no work
for them to do. I wonder if a CP in wait state is using any power at
all? If so, this would be even better that merely throttling.


I can say for my machine: power usage does not depend on current workload.
HMC Activity monitor shows roughly the same value for CPC 90% busy, 5% busy and single LPAR or CPC activated, but completely not in use.

Actually there is "green mode" - when refrigerator (air cooler) is out of order. In such case the clock slow down the cycle. ;-)

--
Radoslaw Skorupka
Lodz, Poland






--
Treść tej wiadomości może zawierać informacje prawnie chronione Banku 
przeznaczone wyłącznie do użytku służbowego adresata. Odbiorcą może być jedynie 
jej adresat z wyłączeniem dostępu osób trzecich. Jeżeli nie jesteś adresatem 
niniejszej wiadomości lub pracownikiem upoważnionym do jej przekazania 
adresatowi, informujemy, że jej rozpowszechnianie, kopiowanie, rozprowadzanie 
lub inne działanie o podobnym charakterze jest prawnie zabronione i może być 
karalne. Jeżeli otrzymałeś tę wiadomość omyłkowo, prosimy niezwłocznie 
zawiadomić nadawcę wysyłając odpowiedź oraz trwale usunąć tę wiadomość 
włączając w to wszelkie jej kopie wydrukowane lub zapisane na dysku.

This e-mail may contain legally privileged information of the Bank and is intended solely for business use of the addressee. This e-mail may only be received by the addressee and may not be disclosed to any third parties. If you are not the intended addressee of this e-mail or the employee authorised to forward it to the addressee, be advised that any dissemination, copying, distribution or any other similar activity is legally prohibited and may be punishable. If you received this e-mail by mistake please advise the sender immediately by using the reply facility in your e-mail software and delete permanently this e-mail including any copies of it either printed or saved to hard drive.
BRE Bank SA, 00-950 Warszawa, ul. Senatorska 18, tel. +48 (22) 829 00 00, fax 
+48 (22) 829 00 33, www.brebank.pl, e-mail: i...@brebank.pl
Sąd Rejonowy dla m. st. Warszawy XII Wydział Gospodarczy Krajowego Rejestru Sądowego, nr rejestru przedsiębiorców KRS 0000025237, NIP: 526-021-50-88. Według stanu na dzień 01.01.2012 r. kapitał zakładowy BRE Banku SA (w całości wpłacony) wynosi 168.410.984 złotych.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to