IEAVTABX.

Real time, when there is a dump. 

Check if SYSMDUMP is to SYSOUT, and then suppress it.

On Tue, 22 Sep 2020 12:11:43 +0000 Mark Jacobs
<00000224d287a4b1-dmarc-requ...@listserv.ua.edu> wrote:

:>We have developers who put SYSMDUMP output to SYSOUT rather than a dataset. 
I'm looking at ways to prevent those jobs from executing until they make JCL 
changes. Are there any other exits, processes other than a JES2 exit (looking 
at exit 6/60) to do so?

--
Binyamin Dissen <bdis...@dissensoftware.com>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

----------------------------------------------------------------------