> IEW2454W 9203 SYMBOL SUDATE UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2454W 9203 SYMBOL CONVER08 UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2454W 9203 SYMBOL SUYYDDDF UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2454W 9203 SYMBOL SUTIME UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2454W 9203 SYMBOL CONVER10 UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2454W 9203 SYMBOL IEFSD095 UNRESOLVED. NO AUTOCALL (NCAL) > SPECIFIED. > IEW2650I 5102 MODULE ENTRY NOT PROVIDED. ENTRY DEFAULTS TO SECTION > SORTTRAK.
Robert, I guess you skipped reading the 2nd line onwards in the SORTTRAK program //*------------------------------------------------------------------ //* //* PGM = SORTTRAK //* THE SOURCE CODE FOR THE DATE CONVERSION SUBROUTINES //* (SUYYDDDF AND SUDATE) AND FOR THE TIME CONVERSION //* SUBROUTINE (SUTIME) IS NOT INCLUDED AS EVERYBODY IS USING //* OWN STANDARDS. ANY HOME WRITTEN CONVERSION SUBROUTINES //* MAY BE IMPLEMENTED. //* //*------------------------------------------------------------------ As for IEFSD095(block char routine), it is a standard MVS procedure.When you link the block character subroutine concatenate the following standard MVS library to the //SYSLIB DD statement:" // DD DSN=SYS1.AOSBØ,DISP=SHR for IEFSDØ95 block character routine Here is the documentation link for IEFSD095 https://www.ibm.com/docs/en/zos/2.1.0?topic=works-using-block-character-routine So the bottom line is to convert the date/time with your own code. Thanks, Kolusu ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN