> IEW2454W 9203 SYMBOL SUDATE UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2454W 9203 SYMBOL CONVER08 UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2454W 9203 SYMBOL SUYYDDDF UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2454W 9203 SYMBOL SUTIME UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2454W 9203 SYMBOL CONVER10 UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2454W 9203 SYMBOL IEFSD095 UNRESOLVED.  NO AUTOCALL (NCAL)
> SPECIFIED.
> IEW2650I 5102 MODULE ENTRY NOT PROVIDED.  ENTRY DEFAULTS TO SECTION
> SORTTRAK.

Robert,

I guess you skipped reading the 2nd line onwards in the SORTTRAK program

//*------------------------------------------------------------------
//*
//*     PGM = SORTTRAK
//*     THE SOURCE CODE FOR THE DATE CONVERSION SUBROUTINES
//*     (SUYYDDDF AND SUDATE) AND FOR THE TIME CONVERSION
//*     SUBROUTINE (SUTIME) IS NOT INCLUDED AS EVERYBODY IS USING
//*     OWN STANDARDS. ANY HOME WRITTEN CONVERSION SUBROUTINES
//*     MAY BE IMPLEMENTED.
//*
//*------------------------------------------------------------------

As for IEFSD095(block char routine), it is a standard MVS procedure.When
you link the block character subroutine concatenate the following  standard
MVS library to the //SYSLIB DD statement:"

// DD DSN=SYS1.AOSBØ,DISP=SHR for IEFSDØ95 block character routine


Here is the documentation link for IEFSD095

https://www.ibm.com/docs/en/zos/2.1.0?topic=works-using-block-character-routine

So the bottom line is to convert the date/time with your own code.

Thanks,
Kolusu



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN