Part of my process moving maint forward is to run a static symbol update, it's a manual process but beats searching for an eyecatcher in a load module for a PTF number

//SYM EXEC PGM=IEASYMU2,PARM='RSU=2102'


On 8/24/2021 5:41 AM, Bill Giannelli wrote:
I have received and applied several months maintenance, but have not yet moved 
it into our runtime libraries. How might I determine what my prior RSU level is 
within my runtime libraries?
thanks
Bill

----------------------------------------------------------------------