I have a question about RMM. We've received some new cartridges that hadn't 
been initialized by the supplier. This caused I/O errors when attempts were 
made to mount the cartridges.To avoid these errors we changed their status to 
INIT so that they wouldn't be mounted:

                   DFSMSrmm Volumes (Page 1 of 2)        Row 100 to 112 of 139
Command ===>                                                  Scroll ===> CSR 
                                                                              
Enter HELP or PF1 for the list of available line commands                     
Use the RIGHT command to view other data columns                              
   Volume          Assigned   Expir./                                         
Dest-    T Data 
S  serial Owner    date       Retn. date Ret Status  Location ination  R sets 
-- ------ -------- ---------- ---------- --- ------- -------- -------- - -----
   700101          15/09/2021            V        INIT    TS3500                
  N 0    
   700102          15/09/2021            V        INIT    TS3500                
  N 0    
   700103          15/09/2021            V        INIT    TS3500                
  N 0    
   700104          15/09/2021            V        INIT    TS3500                
  N 0    
   700105          15/09/2021            V        INIT    TS3500                
  N 0    
   700106          15/09/2021            V        INIT    TS3500                
  N 0    
   700107          15/09/2021            V        INIT    TS3500                
  N 0    
   700108          15/09/2021            V        INIT    TS3500                
  N 0    
   700109          15/09/2021            V        INIT    TS3500                
  N 0    
   700110          15/09/2021            V        INIT    TS3500                
  N 0    
   700111          15/09/2021            V        INIT    TS3500                
  N 0    
   700112          15/09/2021            V        INIT    TS3500                
  N 0    
   700113          15/09/2021            V        INIT    TS3500                
  N 0

However this means that they are still unusable and have been since September. 
All we need to do is initialize them but there's a shortage of RMM knowledge 
around here. Could anyone please give me some advice on how to do this ? It 
would be greatly appreciated. Someone suggested using INITT but I suspect that 
that's not appropriate here.

Regards,
John.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to