Michael Babcock's comment was fully correct and on point.

If you have LOADxx in SYS1.IPLPARM on volume VOL123 and that dataset is not in 
the parmlib concatenation then
SETLOAD xx,IEASYM,DSN=SYS1.IPLPARM,VOL=VOL123
applies.

And, as is described, you can use
SETLOAD xx,IEASYM,DSN=IPL,VOL=IPL
To indicate to take the dataset and volume used from IPL to locate LOADxx.

Colin, what commentary update are you thinking of requesting?
The doc indicates that the default is to locate LOADxx via the parmlib 
concatenation (which is true) and shows how to override the default.
There's almost always room for improvement in documentation....

Peter Relson
z/OS Core Technology Design


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN