On Mon, 20 Jan 2025 09:42:15 -0500, Phil Smith III wrote:
>MODE B and TYPE E are not universal, alas.
>
From a desktop I've tried:
BINARY
QUOTE SITE STRU R
(The desktop didn't accept STRU.) For successful round-trip binary VB data.
Alas, it failed for RECFM VBS, treating each segment as an entire record.
I suspect STRU R has no representation of an incomplete record.
>On 19/01/2025 6:00 am, Kirk Wolf wrote:
>> I'm 99% certain that there are some "site" options in IBM FTP that will
>> round-trip binary VB data. I've seen it discussed on IBM-MAIN, but not
>> for years and I can't recall the details.
--
gil
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN