Thank you Kolusu for pointing that that. I should have seen it. I knew it had bo be something simple that I was missing altogether. Regards
On Mon, Aug 25, 2025, 18:08 Sri Hari Kolusu <[email protected]> wrote: > > TMP-HLQ,1,08,CH * HLQ > > Jack, > > Hope you realized that you destructively overlaid the original record and > started the temp fields at position 1 and then you follow the count fields > as you used OVERLAY instead of BUILD. Ideally, I would start the TEMP > field at the END of the original record. > Something like 81 ie. > > > TMP-HLQ,81,08,CH * HLQ > > Thanks, > Kolusu > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN