On Tue, 26 Aug 2025 12:16:06 +0000, Seymour J Metz <[email protected]> wrote:
>My recollection is that COPYMOD is only valid for DASD-DASD. I only need DASD to DASD. I only need to transport a single load module. And I (basically) have control over the linker (pdld) that will directly produce IEBCOPY (basically) format (artificially produce an unloaded load module). Load modules only exist in DASD, so that's not a problem. It will look like it has been unloaded from a DASD - but the type of DASD is up for grabs. Note that this already exists, but we're trying to clarify what the device characteristics should ideally be for general purpose use. I was thinking 1 record per track, 1 head and up to 65536 cylinders giving a maximum load module size of 384 MiB (with 6144-byte blocks), which is plenty. But the IEBCOPY manual has a different artificial device. But they have a different objective than transporting a single load module. BFN. Paul. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN