Did you apply maintenance to the running system traditional datasets by accident, and a “service” root filesystem that is not the active root filesystem?
_______________________________ Dave Jousma Vice President | Director, Technology Engineering Fifth Third Bank | 1830 East Paris Ave, SE | Grand Rapids, MI 49546 From: IBM Mainframe Discussion List <[email protected]> on behalf of Alain Benvéniste <[email protected]> Date: Tuesday, September 30, 2025 at 10:28 AM To: [email protected] <[email protected]> Subject: Re: GIM69208S + GIM23412S CAUTION EXTERNAL EMAIL This message came from outside your organization. DO NOT open attachments or click on links from unknown senders or unexpected emails. Report Suspicious<https://us-phishalarm-ewt.proofpoint.com/EWT/v1/MwwqYLOC6b6whF7V!rhOLF7EpDg7h34fXDNigVFk50QkiSht0BGJrX6HihqmN-jPg-1OUq0tPw0F-x2XnILBifu1vctLY0tUt0c-dqnhXwenk9OPe$> Kurt, I don’t have a STEPLIB defined. The LLA was refreshed. The problem persists with the same messages. Thanks Resiliency Services on Z Mainframe [email protected] > Le 30 sept. 2025 à 15:29, Kurt Quackenbush <[email protected]> a écrit : > > >> >> GIM69208S ** RECEIVE PROCESSING HAS FAILED BECAUSE THE LEVEL OF PROGRAM >> GIMJVCLT >> (37.34) IS NOT COMPATIBLE WITH THE LEVEL OF THE SMP/E CALLING >> PROGRAM GIMSMP (37.30). > > SMP/E requires program GIMSMP (and similar) to be at the same service level > as its java classes which reside in /usr/lpp/smp/classes/. This message > means they are not at the same service level. > > Are you using a STEPLIB in the job? If so, it contains an older PTF level of > program GIMSMP. Into which data set did GIMSMP get updated when you applied > your recent set of PTFs? Can you STEPLIB to that data set? Your SMPCPATH DD > statement value shows you're using the SMP/E java classes in > /usr/lpp/smp/classes/. Did you refresh LLA after applying the PTFs so that > program fetch will get the more recent program GIMSMP? > > https://urldefense.com/v3/__https://www.ibm.com/docs/en/zos/2.5.0?topic=messages-gim69208s__;!!MwwqYLOC6b6whF7V!k1JmB5jSjw_sPiiHZltCwFi-FNx5GZodlJkVpU9_fTuM86n5ugobUGC9QECToD81dXQbMha8AeEHVBOHeZtQdsJWiqM729GTe_8$ > > Kurt Quackenbush > IBM | z/OS SMP/E and z/OSMF Software Management | [email protected] > > Chuck Norris never uses CHECK when he applies PTFs. > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN