Some compilers use a different code page to interpret their input
because they use a special character not in the usual code page for their
system.

On Wed, Oct 29, 2025 at 12:37 AM Peter Hannigan <
[email protected]> wrote:

> > Date:    Mon, 27 Oct 2025 17:21:50 -0400
> > From:    Phil Smith III <[email protected]>
> > Subject: Re: Code page used bt SMS (and MVS, in general)
> >
> > Sorry, I guess it was 500 that caused us problems -- square brackets are
> > the same in 037 and 1047.
>
> Actually, they're different, and there's four more:
>
>                 037     1047
>
> x'5F'           ¬       ^
> x'AD'           Ý       [
> x'B0'           ^       ¬
> x'BA'           [       Ý
> x'BB'           ]       ¨
> x'BD'           ¨       ]
>
> and 500 has more and different differences.
>
>
> Peter Hannigan
> Kyndryl
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN