Anthony, SAS provided the modifications to PDS86 for access to PDSE's in cylinder managed space on EAV. Download from CBT "Updates" page.
Regards, John K -----IBM Mainframe Discussion List <IBM-MAIN@listserv.ua.edu> wrote: ----- To: IBM-MAIN@listserv.ua.edu From: Anthony Fletcher Sent by: IBM Mainframe Discussion List Date: 07/11/2013 07:29PM Subject: PDS86 EAV compatibility Is anyone, by any chance, working on PDS86 to make it compatible with the EAV DASD support code? The z/OS Tracking facility is listing PDS86 as not having the necessary set up. For example - this is just after emptying the list. RESPONSE=MLCS CNZ1001I 10.26.09 TRACKING DISPLAY 212 STATUS=ON NUM=6 MAX=1000 MEM=00 EXCL=125 REJECT=0 ----TRACKING INFORMATION---- -VALUE-- JOBNAME PROGNAME+OFF-- ASID NUM SMS-E:1 DADSM OBTAIN C10001 DB2ADM SSCLOCT 172 71 2 SMS-E:1 DADSM OBTAIN C10001 LDAXF67 PDS86 3D42 55 1 <-------------------- SMS-E:1 DADSM OBTAIN C10001 LDAXF67 SSCLOCT 172 55 5 SMS-E:1 DCB OPEN EAS 113-44 01 CTDTROLD IOADBS 53E 4F 2 SMS-E:1 DCB OPEN EAS 113-44 01 LDAXF67 PDS86 124 55 1 <-------------------- SMS-W:2 IEHLIST LISTVTOC 02 AXR08 IRXSTAM 1F3A 41 1 ---------------------------------------------------------------------- TO REPORT THESE INSTANCES, SEND THIS MESSAGE VIA E-MAIL TO conso...@us.ibm.com. FOR ADDITIONAL INFORMATION OR TO OBTAIN A CURRENT EXCLUSION LIST, SEE APAR II13752. ---------------------------------------------------------------------- ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN