You're quite welcome. I also belatedly dug into my old JCL data set and
found this:
DEFINE CLUSTER -
(NAME(SYS1.STGINDEX) -
KEYS(12 8) -
CYLINDERS(1) -
BUFFERSPACE(20480) -
RECORDSIZE(2041 2041) -
VOLUME(VOLSER) -
REUSE) -
DATA (CONTROLINTERVALSIZE(2048))
I have absolutely NO idea whether the values above are appropriate or
recommended today, if indeed they were ever recommended. In the MVS/XA
timeframe, however, I believe they worked. I likely lifted this from a
CBIPO at the time (smile).
lon.a.storr....@mail.mil (Storr, Lon A CTR USARMY HRC , US) wrote:
Classification: UNCLASSIFIED
Caveats: NONE
John,
Thank you for a pertinent, clear and precise answer to my query. I am
quite content to use VIODSN=IGNORE but, because STGINDEX is still utilized at
many of the shops I visit, I was looking for (and unable to find) the
documentation.
<snip>
--
John Eells
z/OS Technical Marketing
IBM Poughkeepsie
ee...@us.ibm.com
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN