That is what I decided to do (Name Token pair).  Made life a lot easier

Steve  

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of [email protected]
Sent: Wednesday, October 21, 2015 2:58 PM
To: [email protected]
Subject: Re: ALESERV macro

I agree with Chris Blaicher solution.
If the exit does not run the the address space a System Level Name Token
Pair would be an elegant method to retrieve the ALET and Address of the Data
Space. I have used it in an MQ exit and it works well.

Paul V. DAngelo 

---------- Original Message ----------
From: "Blaicher, Christopher Y." <[email protected]>
To: [email protected]
Subject: Re: ALESERV macro
Date: Wed, 21 Oct 2015 18:17:30 +0000

Look up NAME/TOKEN services.  You have 16 bytes in it for user data.  Part
of that could be the ALET of the data space.

Chris Blaicher
Technical Architect
Software Development
Syncsort Incorporated
50 Tice Boulevard, Woodcliff Lake, NJ 07677
P: 201-930-8234  |  M: 512-627-3803
E: [email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Steve Beaver
Sent: Wednesday, October 21, 2015 1:37 PM
To: [email protected]
Subject: Re: ALESERV macro

I assume this exit is not running in the STC's address space? CORRECT The
EXIT is a IEFU85 that has been DYNAMICALLY installed

I would like to say with DataSpaces if at all possible

Steve

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of John McKown
Sent: Wednesday, October 21, 2015 10:26 AM
To: [email protected]
Subject: Re: ALESERV macro

I assume this exit is not running in the STC's address space? Are you open
to an alternative to a Data Space? If so, I would humbly suggest considering
whether using an AMODE(64) object in HVCOMMON might be easier.
You can save it's address in a global name/token pair. Or, if you're really
"into" it, you could have your STC set itself up with an SSVT and anchor
things in it.

ref:
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/iea2a2b0/25.0

On Wed, Oct 21, 2015 at 12:16 PM, Steve Beaver <[email protected]>
wrote:

> In a STC I have created a DataSpace.  But in an EXIT I need to use the 
> ALESERV macro
>
> The exit only knows nothing essentially.  So the question becomes  how 
> can the EXIT Address The DataSpace so I can issue a MVCL to the 
> DataSpace
>
> I hate to be a pain but I have never done this.
>
>
> Steve
>
>

--

Schrodinger's backup: The condition of any backup is unknown until a restore
is attempted.

Yoda of Borg, we are. Futile, resistance is, yes. Assimilated, you will be.

He's about as useful as a wax frying pan.

10 to the 12th power microphones = 1 Megaphone

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

________________________________



ATTENTION: -----

The information contained in this message (including any files transmitted
with this message) may contain proprietary, trade secret or other
confidential and/or legally privileged information. Any pricing information
contained in this message or in any files transmitted with this message is
always confidential and cannot be shared with any third parties without
prior written approval from Syncsort. This message is intended to be read
only by the individual or entity to whom it is addressed or by their
designee. If the reader of this message is not the intended recipient, you
are on notice that any use, disclosure, copying or distribution of this
message, in any form, is strictly prohibited. If you have received this
message in error, please immediately notify the sender and/or Syncsort and
destroy all copies of this message in your possession, custody or control.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN