I should have added that we specify DUPLEX=on, which means all updates go to both. _________________________________________________________________ Dave Jousma Manager Mainframe Engineering, Assistant Vice President david.jou...@53.com 1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f 616.653.2717
-----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Jousma, David Sent: Tuesday, August 23, 2016 11:15 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Backup JES2 Spool & Restore with Warmstart That’s what we do. Primary in the CF, secondary on disk. When we recover to our DR systems, we restart JES and it prompts us that the primary is missing, and do we want to start from the secondary. Can't say we have ever noticed a problem. _________________________________________________________________ Dave Jousma Manager Mainframe Engineering, Assistant Vice President david.jou...@53.com 1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f 616.653.2717 -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Jesse 1 Robinson Sent: Tuesday, August 23, 2016 11:05 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Backup JES2 Spool & Restore with Warmstart A question that just occurred to me: Where does your primary checkpoint live? This is pretty ancient history, but in the mid-90s when we first went to parallel sysplex, I tried putting the primary checkpoint in the coupling facility. This meant that the secondary checkpoint was the only one mirrored. Or flashed, if we had had that technology then. The secondary is not updated as often as the primary. Just wondering... . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-302-7535 Office robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Mike Shorkend Sent: Monday, August 22, 2016 10:09 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: Backup JES2 Spool & Restore with Warmstart One of my customers does a daily flash copy and then IPLs off the copy. No issues with JES2 warm start. They are using DS8870 and z/OS 2.2 but have been doing this for years without problems. HTH Mike On 23 August 2016 at 04:46, Ron Hawkins <ronjhawk...@sbcglobal.net> wrote: > Ken, > > FlashCopy consistency group "should" give you the same P-i-T as Synch > and Asynch Remote Copy. Sounds like you should report a problem. > > Attended a few DR rehearsals where JEs2 has warm started without a hitch. > > Have you tried ShadowImage At-Time split (if you have HDS)? > > Ron > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] > On Behalf Of Ken Smith > Sent: Monday, August 22, 2016 8:16 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: [IBM-MAIN] Backup JES2 Spool & Restore with Warmstart > > I've not had the opportunity to work with mirroring but sounds like > your flashcopy to secondary is the same thing I'm doing minus the > transmission. > And, the purpose of a consistency group is to have a point in time > copy across volumes. > > Anyone else? Ken > > On Thu, Aug 18, 2016 at 5:44 PM, Jesse 1 Robinson > <jesse1.robin...@sce.com > > > wrote: > > > We've been mirroring for DR for many years. In the beginning, with > > late 90s technology, we could not mirror spool. Now with FICON over > > DWDM we mirror spool routinely. I can't remember getting any error > > on > > JES2 restart after recovery, which includes flashcopy of the > > secondary (XRC target) copy to a tertiary copy that we IPL from. > > > > . > > . > > . > > J.O.Skip Robinson > > Southern California Edison Company > > Electric Dragon Team Paddler > > SHARE MVS Program Co-Manager > > 323-715-0595 Mobile > > 626-302-7535 Office > > robin...@sce.com > > > > > > -----Original Message----- > > From: IBM Mainframe Discussion List > > [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Ken Smith > > Sent: Thursday, August 18, 2016 12:55 PM > > To: IBM-MAIN@LISTSERV.UA.EDU > > Subject: (External):Backup JES2 Spool & Restore with Warmstart > > > > For those of us stuck with tape backup, physical or virtual, are you > > recovering JES2 and able to do a warm start? > > > > I made the rash assumption that Flashcopy (space efficient) with > > consistency group across the spool and checkpoint volumes would > > work, but it does not - get checkpoint errors and have to do a > > format and cold > start. > > > > Read in JES2 manual that back up is not supported, however, not sure > > this was written before or after flash copy was invented. Seems to > > me that at any instant in time the data should be consistent? Also, > > disk mirroring should have the same problem but I doubt it does. > > > > Thoughts? > > > > Ken Smith > > Comptroller of Maryland -- Mike Shorkend m...@shorkend.com www.shorkend.com Tel: +972524208743 Fax: +97239772196 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN