Also,  looking into why there are STARTING tasks and stopping it would be a 
good idea :)

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU]
> On Behalf Of Lizette Koehler
> Sent: Wednesday, November 02, 2016 10:20 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: Cancel STARTING
> 
> Not sure of your question.
> 
> However,  C STARTING,A=xxxx
> 
> Says to cancel the task STARTING in the Address Space xxxx
> 
> You may have multiple tasks in Starting Status, this allows you to cancel a
> specific STARTING in an specific ASID.
> 
> If you do CANCEL STARTING, I think z/OS would not know what to do with that.
> 
> 
> Lizette
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU]
> > On Behalf Of Nathan Astle
> > Sent: Wednesday, November 02, 2016 10:14 AM
> > To: IBM-MAIN@LISTSERV.UA.EDU
> > Subject: Cancel STARTING
> >
> > Hi
> >
> > Apology for asking a dummy question.
> >
> > When we have multiple STC in starting status. We issue C
> > STARTING,A=XXXX
> >
> > Does it mean we are cancelling just based on Cancel status ?
> >
> > Nathan
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to