WAD.

What if job #1 now allocates +2? 

+1 remains that thru the job.

On Tue, 12 Sep 2017 11:54:04 -0500 Kirk Wolf <k...@dovetail.com> wrote:

:>Is there a way around this?
:>
:>Even with SMS-managed GDGs, where the generation is cataloged at
:>allocation, two jobs that dynamically allocate +1 generations (with GDGNT)
:>will collide.
:>
:>For example, from two different jobs:
:>
:>(job 1)
:>./bpxwdyn.rexx "alloc fi(mydd) da('managed.test.gdg(+1)') recfm(v,b) new
:>catalog gdgnt lrecl(1028)"
:>BPXWDYN RC= 0  (0x0)
:>
:>(job 2)
:>./bpxwdyn.rexx "alloc fi(mydd) da('managed.test.gdg(+1)') recfm(v,b) new
:>catalog gdgnt lrecl(1028)"
:>
:>BPXWDYN RC= 34603008  (0x2100000)
:>IKJ56225I DATA SET MANAGED.TEST.GDG ALREADY IN USE, TRY LATER+
:>IKJ56225I DATA SET IS ALLOCATED TO ANOTHER JOB OR USER
:>IEFA110I DATA SET CONTENTION
:>...
:>
:>Kirk Wolf
:>Dovetailed Technologies
:>http://dovetail.com
:>
:>----------------------------------------------------------------------
:>For IBM-MAIN subscribe / signoff / archive access instructions,
:>send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

--
Binyamin Dissen <bdis...@dissensoftware.com>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to