Doing the define NONVSAM - got me a little closer - the dataset is now
cataloged.  But when I use D to delete the datset -

IEC614I SCRATCH FAILED - RC 008, DIAGNOSTIC INFORMATION IS (04060020),
IKJACCNT,STDL09,MARPACE.GODADDY.CERT

04060020 -  Verification of SMS flags failed; caller indicates data set is
not SMS-managed, but FMT4 DSCB indicates that it is an SMS volume. This
error might be caused by a damaged catalog entry. Issuing the recatalog
command might clear this error.

Do I will try the recatalog command.

On Thu, Feb 8, 2018 at 2:44 PM, Burrell, Todd <todd_burr...@csx.com> wrote:

> What do you get if you try this in IDCAMS:
>
>   DEFINE NONVSAM(NAME(MARPACE.GODADDY.CERT) -
>          DEVT(3390) VOLUME(STDL09))
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
> Behalf Of Mark Pace
> Sent: Thursday, February 08, 2018 2:38 PM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Delete dataset catch-22
>
> I'm trying to delete a dataset that is not cataloged any longer.  I'm not
> sure why it is not in a catalog, but it is not.  I've tried to re-catalog
> the dataset, but it doesn't catalog.
>
> So I have tried to every combination of IDCAMS DELETE I can think of.
> NONVSAM
> NVR
> etc..
>
> All return
> ** VSAM CATALOG RETURN CODE IS 8 - REASON CODE IS IGG0CLEG-42  - Dataset
> not found.
>
> So I tried IEHPROGM
>   SCRATCH DSNAME=MARPACE.GODADDY.CERT,VOL=3390=STDL09,PURGE
>
> IEC614I SCRATCH FAILED - RC 008, DIAGNOSTIC INFORMATION IS (0406001E),
> STEP010,STDL09,MARPACE.GODADDY.CERT
>
> 0406001E -  Verification of SMS flags failed; caller indicates the data
> set is not cataloged, but the *FMT1 DSCB indicates the data set is
> cataloged*
>
> So I have no idea how to remove this dataset, IDCAMS won't do it because
> it's not in a catalog, and IEHPROGM won't do it because it thinks it is in
> a catalog.
>
> Anyone have a suggestion?
>
> Thank you.
>
>
>
> --
> The postings on this site are my own and don’t necessarily represent
> Mainline’s positions or opinions
>
> Mark D Pace
> Senior Systems Engineer
> Mainline Information Systems
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
>
>
> This email transmission and any accompanying attachments may contain CSX
> privileged and confidential information intended only for the use of the
> intended addressee. Any dissemination, distribution, copying or action
> taken in reliance on the contents of this email by anyone other than the
> intended recipient is strictly prohibited. If you have received this email
> in error please immediately delete it and notify sender at the above CSX
> email address. Sender and CSX accept no liability for any damage caused
> directly or indirectly by receipt of this email.
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>



-- 
The postings on this site are my own and don’t necessarily represent
Mainline’s positions or opinions

Mark D Pace
Senior Systems Engineer
Mainline Information Systems

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN