On Tue, Jan 15, 2019 at 01:29:46PM -0500, Jim Mulder wrote: > WAIT processing was rewritten for MVS/XA, and the check for > the communications ECB is in the mainline code, not in the FRR.
Great! > There is no level of IEAVEWAT older than MVS/XA in our code > repository, which suggests that WAIT processing was in a different > module in MVS/370. I don't know which module that > was, so I can't look to see how it worked. On MVS 3.8 IEAVSY50 includes both wait and post. Validity check is in IEAVEVAL. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN