This problem is fallout from allowing test (or dev) to share resources, including identities, with production. It's worse than 'blurring a line'. It's defining a coin whose head and tail belong to different creatures. When we embarked on sysplex in the mid-90s, we created plexes by duplicating existing systems so that each sysplex today contains (more or less) the same DNA as one original system. Each plex shares data--SAF, HSM, catalogs, etc.--only with like systems. As Max says, you can't swap personalities mid-stream.
. . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Max Smith Sent: Wednesday, January 30, 2019 11:58 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: ARC1139I RC39 RSB08 Munif, There is nothing in HSM that will allow that RECALL to work. You can set up HSM to not allow the test system to RECALL data sets by issuing this command on the test system HOLD COMMONQUEUE(RECALL) This allow the test system to put RECALL requests on the queue just not process any requests that are on the CRQ. Max Smith DFSMShsm Development ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN