Here is the control statement :

SMPCNTL DD *
SET BDY TZONE .
APPLY CHECK
GROUPEXTEND
BYPASS((HOLDSYSTEM))
RETRY(YES)
.


On Sun, 25 Aug, 2019, 4:30 PM David Spiegel, <dspiegel...@hotmail.com>
wrote:

> Hi Peter,
> - Modifying vendor-supplied MCS is NEVER a good idea.
> - The messages means that you are trying to APPLY a lower-level PTF than
> is currently APPLYd.
> (Do you really want to back-level your software?)
> It would be helpful to supply your entire //SMPCNTL when asking
> questions of this nature.
> That is, there is not enough context to decipher what you're attempting.
>
> Regards,
> David
>
> On 2019-08-25 03:21, Peter wrote:
> > Hi
> >
> > I am apply RSU for our zOS system. I am receiving a error message
> >
> > GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY EZBTCRDF IN SYSMOD
> UI34556
> >
> > GIM31901I SYSMOD UI34556 DOES NOT SPECIFY UI46897 ON PRE OR SUP OPERAND.
> > UI46897 IS THE RMID FOR MOD EZBTCRDF THAT IS CURRENTLY INSTALLED.
> >
> > GIM22601I  APPLY PROCESSING FAILED FOR SYSMOD UI34556.
> >
> > Does it mean the PTF UI46897 applied should be restored and modify its
> MCS
> > to add UI34556 as its PRE ?
> >
> > Is my understanding correct?
> >
> > Could someone please shed light on ?
> >
> > zOS 2.2
> >
> > Peter
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> > .
> >
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to