This seems to be a lot of work to recover a very small amount of data.

There are so few options in the SADMP program, that it would probably be faster 
to code it up from scratch.

Check the fine manuals for details on the macro coding.



HTH,





-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Shivang Sharma
Sent: Tuesday, August 27, 2019 10:13 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Reverse map Adsadmp parms



Thanx Jim , that was beneficial.

One additional question, I can see

the PL/s structure defined in

Amdsaddo which has pointers to

different sections for example

a pointer to console options.

So how we can convert these pointers

in terms of character position (offset)

to identify the start of each section.



Thanks in advance.



----------------------------------------------------------------------

For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu<mailto:lists...@listserv.ua.edu> with the message: 
INFO IBM-MAIN

::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to