Please provide the complete error message. The error message does not address tape labels. (A wrong label would produce a system error before DFDSS got to the tape.) It says the sequence number of data records is wrong. This may indicate a corrupt file.
What system level are you at. There is a 5 year old APAR that addresses this issue. > -----Original Message----- > From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On > Behalf Of Nai, Dean > Sent: Wednesday, November 13, 2019 11:55 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: DFDSS backup retore > > Has anyone ever run into a problem where they have full volume backups that > produce > a ADR370E message when trying to restore? That message says the label and DSN > on > the tape don't match although I know they do. Any thoughts? > > Control cards: > > Restore - > Admin - > Inddname(indd1) outddname(outdd1) - > Full purge copyvolid > > //indd1 dd > dsn=backup.dly.smflgb.g0449v00,label=(1,sl),unit=tape,disp=old,vol=ser=tap001 > //outdd1 dd vol=ser=sc560c,unit=3390,disp=old > > Dean Nai ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN