What documentation there is, is in SC27-3659 IP Programmer's Guide and Reference Appendix E. Anything more than that you will need to ask IBM/
HTH, -----Original Message----- From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of Pierre Fichaud Sent: Tuesday, March 17, 2020 8:28 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: SMF 119 records (TCPIP) [CAUTION: This Email is from outside the Organization. Do not click links or open attachments unless you trust the sender.] There are many sub-types for SMF 119 (X'77'). The common identification section has a flag byte called SMF119TI_Reason with the following values: X'C0' - Interval record, more records to follow X'80' - Interval record, last record in set X'60' - End of statistics record, more records to follow X'40' - End of statistics record, last record in set x'50' - Shutdown starts record, more record to follow x'10' - Shutdown starts record, last record in set X'48' - Events record, more records to follow x'08' - Events record, last record in set Is there a more detailed explanation of these values ? Can interval records be ignored if one takes the end of statistics records ? I guess shutdown starts records are cut when TCP/IP starts to shutdown ? When is an event record cut ? Can SMF119TI_RecordId be used to tie together different records of the same sub-type? Regards and TIA, Pierre. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ::DISCLAIMER:: ________________________________ The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ________________________________ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN