thank you Bill, this helps me very much.

Franz Josef

> --- Ursprüngliche Nachricht ---
> Von: Bill Stephens <[EMAIL PROTECTED]>
> An: IBMVM@LISTSERV.UARK.EDU
> Betreff: Re: [IBMVM] EMC Symmetrix Model 5830 Shutdown/Startup question
> Datum: Mon, 20 Mar 2006 07:02:29 -0500
> 
> Excerpted from Symmetrix Models 3830/5830 Product Manual in
> the "Power Sequences" chapter:
> 
> 
> Routinely Powering Up the Symmetrix 3830/5830
> 
> Perform these steps to power up the Symmetrix after it has been
> powered off by the AC power switch.
> 
> 1. Press the AC power switch on the rear door to the up (|) position.
> Symmetrix begins its IML procedure.
> The power controls are inoperative unless the Emergency Power Off
> (EPO) switch on the rear door is in its enabled (up, | position).   The
> EPO switch when turned off (down, O position) disables all power
> to Symmetrix including the backup battery systems.
> 
> 2. Wait at least twenty minutes for the IML procedure to complete.
> 
> 3. Ensure that the channel director operator panel switches on the
> front door of the Symmetrix are in the enable position before
> attempting to initialize the host.
> 
> 
> Routinely Powering Down the Symmetrix 3830/5830 System
> 
> Perform these steps to power off Symmetrix using the AC power switch.
> 
> CAUTION !  Do NOT use the red EPO switch located on the back of the
> Symmetrix to routinely power down the unit.  The red EPO switch is for
> Emergency shutdown.
> 
> 1. Stop all processes to the Symmetrix 3830/5830.
> 
> 2. Watch the operator panel and wait for all “Active” LEDs to stop
> flashing.
> The displays stop flashing when the Symmetrix has written all cache data
> to disk.
> 
> 3. Press the black AC IN power switch on the rear door to the down or off
> (0)
> position. Do not press the EPO (red) switch.  The battery backup system
> automatically turns on when Symmetrix detects loss of AC power.  The
> battery will keep Symmetrix powered for 3 minutes following which
> Symmetrix turns off.
> 
> Hope this helps.
> 
> Regards,
> Bill Stephens
> Sr. Technology Analyst, High Availability
> SunGard Availability Services
> 10th floor
> 401 North Broad Street
> Philadelphia, PA 19108
> Phone: (215) 351-1099
> Fax: (215) 451-2045
> [EMAIL PROTECTED]
> ___________________________________________
> Keeping People and Information Connected (TM)
> http://www.availability.sungard.com
> 
> 
> 
>                                                                           
>              Franz Josef                                                  
>              Pohlen                                                       
>              <fjpohlen-maillis                                          To
>              [EMAIL PROTECTED]>                 IBMVM@LISTSERV.UARK.EDU       
>      
>              Sent by: The IBM                                           cc
>              z/VM Operating                                               
>              System                                                Subject
>              <[EMAIL PROTECTED]         EMC Symmetrix Model 5830           
>              ARK.EDU>                  Shutdown/Startup question          
>                                                                           
>                                                                           
>              03/20/2006 06:21                                             
>              AM                                                           
>                                                                           
>                                                                           
>              Please respond to                                            
>                The IBM z/VM                                               
>              Operating System                                             
>              <[EMAIL PROTECTED]                                            
>                  ARK.EDU>                                                 
>                                                                           
>                                                                           
> 
> 
> 
> 
> cross-posted to VM and VSE lists
> 
> Hi listers,
> 
> at next weekend one of my customers needs to power-off an EMC Symmetrix
> Model 5830. I don't know anything about this machine. Can anybody who has
> such a machine tell me if there is anything special to pay attention to
> when
> shutting down and restarting this machine or is is just switch off and
> switch on the power-button.
> 
> Regards
> 
> Franz Josef
> 
> --
> Bis zu 70% Ihrer Onlinekosten sparen: GMX SmartSurfer!
> Kostenlos downloaden: http://www.gmx.net/de/go/smartsurfer
> 

-- 
Bis zu 70% Ihrer Onlinekosten sparen: GMX SmartSurfer!
Kostenlos downloaden: http://www.gmx.net/de/go/smartsurfer

Reply via email to