Thanks Duane, but I didn't explain my part of the question properly (not
the first time huh). What I meant was if the chipd is online to VM and
and is needed by MVS we can move thse on the fly with the config on/off
command. But what would you do to bring that chpid offline to a running
VM system so MVS could access it? Is there a similar command to the
config command on VM?

Mace  

-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Duane Weaver
Sent: Wednesday, December 20, 2006 10:02 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: IOCP dynamic reconfiguration

Larry,


The devices should be added to the Offline_at_IPL statement in the 
SYSTEM CONFIG file for the VM system, located on MAINT's CF1 disk.





At 09:42 AM 12/20/2006, you wrote:
> From mvs (master console) you'd cf(config) the chipid online(on),then
>vary the path and the devices online. What I don't know is what you'd
do
>to have it offline to VM so those devices wouldn't rec an interrupt
from
>VM.
>
>Mace
>
>-----Original Message-----
>From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
>Behalf Of Shimon Lebowitz
>Sent: Wednesday, December 20, 2006 5:02 AM
>To: IBMVM@LISTSERV.UARK.EDU
>Subject: IOCP dynamic reconfiguration
>
>This looks like an MVS question, but it's really not -
>I do all the IOCP preparation from VM, for both the
>VM and the MVS boxes, and have to
>explain to the MVS people why it's not necessary to
>do it in MVS for that box.
>
>In my IOCP I have CVC channels (ESCON Converter
>to parallel [bus/tag] devices) defined with
>  PART=(MVSPROD,REC)
>so that they will be reconfigurable.
>
>In the IOCP listing, these channels show up with
>MVSPROD as the Accesslist, and all other LPARs
>as 'C' - the Candidate list.
>
>In order to move the channel from MVSPROD to
>a different LPAR, we used the 'Reconfigure' item
>in the HMC, but our MVS consultant says we should
>have been able to just vary the path online in the other
>MVS. He suggested that I change the PART=
>to read like this:
>  PART=((MVSPROD),(MVSTEST,SYSTST),REC)
>
>I tried compiling an IOCP like that, and it looked to
>me like all I achieved was to *decrease* my candidate
>list from *all* LPARs, to only the named ones.
>
>Does anyone here have experience with moving
>reconfigurable paths from within an O/S, without
>going to the HMC? What needs to be done to
>enable that function?
>
>It occurs to me that perhaps I just need to
>change the IODF of the other MVS to know
>about this channel, even though it finds it offline.
>Would that do the trick? If so, what would be
>the solution for VM LPARs? (Hmm.. put the
>offline channels in DMKRIO?? <g>)
>
>Thanks,
>Shimon
>--
>**********************************************************************
>**
>Shimon Lebowitz                mailto:[EMAIL PROTECTED]
>VM System Programmer           .
>Israel Police National HQ.     http://www.poboxes.com/shimonpgp
>Jerusalem, Israel              phone: +972 2 530-9877  fax: 530-9308
>**********************************************************************
>**
>-----------------------------------------
>********************************************************************
>The information transmitted is intended solely for the individual or 
>entity to which it is addressed and may contain confidential and/or
>privileged material. Any review, retransmission, dissemination or 
>other use of or taking action in reliance upon this information by 
>persons or entities other than the intended recipient is prohibited. 
>If you have received this email in error please contact the sender 
>and delete the
>material from any computer.
>********************************************************************

Reply via email to