On Thu, Jan 11, 2007 at 01:05:52PM -0500, David L. Craig wrote: > > DEFFCB doesn't get around the problem. I just found the > LOADBUF command writeup and I'm going to try telling it > to use FCB1.
I started with START cuu FCB FCB1 and that seemed to make it happy, but later a missing interrupt caused it to drain followed by an intervention required. The Barr channel server needed some care and when I was told it should be back in service, I did a LOADBUF cuu FCB FCB1 INDEX 01 NOFOLD (successfully) before I did the START. This time it seems to be working. What I don't understand is why ALL the printers on the channel server now show: NOFOLD IMAGE IMAG3211 CHARS A11 FCB FCB1 INDEX 1 LPP 066 when before IMAGE, CHARS, and FCB were blank. I didn't do anything with their FCBs and I don't think CP is smart enough to know they're all being serviced by the same box. (?) -- May the LORD God bless you exceedingly abundantly! Dave Craig - - - - - - - - - - - - - - - - - - - - "'So the universe is not quite as you thought it was. You'd better rearrange your beliefs, then. Because you certainly can't rearrange the universe.'" --from _Nightfall_ by Asimov/Silverberg