OK thanks Les..
I guess my question was poorly worded, I don't want to skip to CH 12, just to 
CH 1..
I should have left the CH 12 stuff out it was confusing..
Tom



-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]
Behalf Of Les Geer (607-429-3580)
Sent: Thursday, May 08, 2008 3:46 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: RSCS LPR ??


>I have a report that has some simple carraige control in it .... SKIP to
>CH 1 (line 2) and CH 12 (line 44).
>
>I want to print this report on a LPR printer via RSCS.
>
>How do I get the printer detect the CH 12 and skip to CH 1.

RSCS LPR exit LPRXONE does handle a skip to channel 1 opcode, converting
to the appropriate CR/FF.  However, it will ignore a skip to channel 12.

Best Regards,
Les Geer
IBM z/VM and Linux Development

Reply via email to