Steve,
 
I'm a little confused by your reply for R/R processing.
 
For minidisks, the MDISK statement in the directory allows you to
specify access modes with MWV where the 'V' stands for CP's simulation
of virtual R/R processing. In this case, for a minidisk, I always
thought that CP would simulate the R/R processing but CP would also
change the R/R CCW to a SENSE CCW. Moreover, if the real DASD where the
minidisk is allocated is defined to CP as SHARED, CP was obligate to
send the R/R CCW to the hardware.
 
For dedicated DASD to a virtual machine, if the dedicated device is
defined to CP as SHARED, the CP will pass the R/R CCW to the hardware.
If the dedicated DASD is not defined as SHARED, CP will change the R/R
CCW to a NOP or SENSE CCW, I can't remember which. 
 
I can't think of any configuration combination where CP would treat a
R/R CCW as a command reject. 
 
OK, I know it's Friday and I may be having a really bad 'senior moment'
here, so I would appreciate any clarification you have for this topic.
 
TIA
 
HITACHI
 DATA SYSTEMS 
Raymond E. Noal 
Senior Technical Engineer 
Office: (408) 970 - 7978 
 
________________________________

From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Steve Wilkins
Sent: Friday, September 26, 2008 8:52 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Reserve/Release
 
For minidisks (fullpack included): It will be rejected (Command Reject)

For dedicated: It hits the iron (i.e., goes to the hardware).

Steve Wilkins
IBM VM Development