I'm about to POR a new IOCP to support Dynamic I/O.

I added to IOCP on the RESOURCE statement:

               MAXDEV=(MAX)

Performed a "Disable write protect" and wrote (WRTA1) the IOCP with the
DYN operand.  The output from the IOCP command stated:

QUERY TOKEN command return code was: 6816   
Processing will continue with default token.

Is this okay?  Do I need to create a TOKEN (with SET TOKEN)?   If not,
is there any advantage to creating this TOKEN?

TIA,

Frank M. Ramaekers Jr.
Systems Programmer                   MCP, MCP+I, MCSE & RHCE
American Income Life Insurance Co.   Phone: (254)761-6649
1200 Wooded Acres Dr.                Fax:   (254)741-5777
Waco, Texas  76710

_____________________________________________________