Thanks Alan.  Yes, I know that degaussing will mess the tape up.  In my
case, I do this when I want to retire the tapes and send them for recycling.

Where do one go to submit a requirement?

> -----Original Message-----
> From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
> Behalf Of Alan Altmark
> Sent: Thursday, October 08, 2009 2:26 PM
> To: IBMVM@LISTSERV.UARK.EDU
> Subject: Re: zVM 'disk wiping'
> 
> On Thursday, 10/08/2009 at 01:55 EDT, Aria Bamdad <a...@bsc.gwu.edu>
> wrote:
> > It would be nice if the CMS TAPE command had a DSE option.  I pass
> tapes
> > through a degausser but would feel a lot better if I ran a DSE
> command
> where
> > the tape was erased from beginning to end.
> 
> Yes, it would be.  But it won't ever be done if people don't submit
> requirements or get their names attached to existing ones.  :-)
> 
> The one thing you must not to do a tape cartridge is degauss it.  If
> you
> do, the servo tracks are destroyed and must be re-initialized before
> the
> tape can be used.
> 
> z/OS will prompt you and ask if it is ok to initialize a scrogged tape.
> z/VM will not.  (Another opportunity for a requirement.)
> 
> Alan Altmark
> z/VM Development
> IBM Endicott

Reply via email to