This may have been asked before but I was wondering the best way to 
Automatically log off a CMS user after a designated time frame. This is to 
address an Audit finding.

If your users log in via tn3270, you can use idle timeouts in the TCPIP virtual 
machine to kill idle connections, and let the CP READ time bomb take care of 
it.   Otherwise, if you have PERFKIT or something similar, there is a idle 
timer in those products where you can use the information gathered by the 
performance monitor to determine when a user has been idle for a period of 
time, and take a useful action (eg, detach devices and then force them off).