Hello George,

 

Yes as long as your 2nd level machine has the disk attached to it.

 

Now the usual warning that you are running with two sets of CP labeled
disks.  If anything happens that cause you to 

Reipl z/VM you could have some issues.

 

Look back at the archives and you will find how to adjust the names of
your 2nd level z/VM system.

 

Ed Martin

Aultman Health Foundation

330-363-5050

ext 35050

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of George Henke/NYLIC
Sent: Tuesday, September 28, 2010 4:34 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Applying Maintenance - Best Practice

 


Can I bring up z/VM Level 2 wiith the same cloned volser's, directory,
and CF parm disks as z/VM Level 1 as long as I  point to the cloned
540RES and FORCE start when I IPL? 

I have  DDRed my 540RES, 540W01, 540W02, Level 1 disks to separate disks
and they now have the same volsers. 

Do I need to also DDR the PAG and SPL disks or can I just FORCE start
with empty disks. 

The directory and CF parm disks came over with 540RES.  Since the names
have not changed Is their "referential integrity" still intact? 

  





Reply via email to