Hi Shanshan,

A few questions:

  1. Are the normalization orders the same?  (Click the Show additional 
parameters button in the background removal section to see that parameter.)
  2. Are the values of spline clamps the same.  (Also visible among the 
additional parameters.)
  3. Are the numerical values associated with the spline clamps the same?  (The 
values are set among the preferences.  Look for the Clamp group on the 
preferences dialog.)

Another thing to look at is the contents of the Ifeffit buffer immediately 
after making those plots.  Are there any obvious differences in the commands 
sent to Ifeffit on the two platforms?

B



--
 Bruce Ravel  ----------------------------------- [EMAIL PROTECTED]

 National Institute of Standards and Technology
 Synchrotron Methods Group at Brookhaven National Laboratory
 Building 535A
 Upton NY, 11973

 My homepage:    http://cars9.uchicago.edu/~ravel
 EXAFS software: http://cars9.uchicago.edu/~ravel/software/exafs/




-----Original Message-----
From: [EMAIL PROTECTED] on behalf of Shanshan Liu
Sent: Wed 12/12/2007 12:58 PM
To: ifeffit@millenia.cars.aps.anl.gov
Subject: [Ifeffit] different edge step by linux and window vista
 
Dear all,

It seems there is a problem when I use athena to open the file under the
windows vista environment.
 
According to the specific scan channel, the data gave the big different
edge step by linux and windows.(Other parameters are similar), and the
figures seem strange(I do not know what caused it). Now I am sending the
screen-shot that I see. Please help me about that.


Thank a lot.

Shanshan Liu

BCPS Dept.
Illinois Institute of Technology 


<<winmail.dat>>