Dear Mohamed,
There is an example of CeO2 EXAFS analysis, taking into account
background problems,
in the following paper:
*J. Padežnik Gomilšek, I. Kozjek-Škofic, N. Bukovec, A. Kodre
*/X-ray absorption study of CeO2 and Ce/V mixed oxide thin films
obtained by sol-gel deposition. /*
*Thin solid films, vol. 446, issue 1, (2004) 117-123.
regards
Iztok Arcon
mohamed sobhy wrote:
Dear all
I am trying to use artemis to do fitting to CeO2. But really I cant
get the right way to do that.
During the fitting, I am using amp as set and change in N degeneracy
of the path. attached is the best fit i got but it still not good and
the chi-square is 41.109065479
so can you suggest me what to do
thanks
Mohamed
------------------------------------------------------------------------
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
--
Iztok Arcon
University of Nova Gorica
Vipavska 13, POB 301
5001 Nova Gorica, Slovenia
tel: +386 5 331 5227
fax: +386 5 331 5240
e-mail: iztok.ar...@ung.si
http://www.ung.si/~arcon
http://www.ung.si/~arcon/xas
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit