Dear Monica: The Lytle database is not in a current standard format. I do have a program to convert it but as Edmund has pointed out, you can find better and more complete data set on the IXS database or just ask any one of us who routinely run Ti edges at a synchrotron.
Carlo On Tue, Jul 6, 2021 at 9:29 AM Monica Bairagi <monicabairag...@gmail.com> wrote: > Hello all: > > I am looking forward to standard metal foil data of titanium. > > I downloaded the data from the Farrel Lytle database but I can not import it > into Athena. I looked into the data, it looked wired for me. As Athena > expects data to be in columns of energy but this data is not recorded by > energy but by steps of the monochromator rotation stage. > I am wondering if anyone has any idea how to import or transfer the data. > I am attached herewith the data file. > > Thanks > Monica Bairagi > Ph.D. Student, Ujjain, India > > _______________________________________________ > Ifeffit mailing list > Ifeffit@millenia.cars.aps.anl.gov > http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit > Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit > -- Carlo U. Segre -- Duchossois Leadership Professor of Physics Professor of Materials Science & Engineering Director, Center for Synchrotron Radiation Research and Instrumentation Illinois Institute of Technology Voice: 312.567.3498 Fax: 312.567.3494 se...@iit.edu http://phys.iit.edu/~segre se...@debian.org
_______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit