Dear all,
Please consider the following small macro:
        run("Set Measurements...", "area display redirect=None decimal=4");
        run("Blobs (25K)");
        makeRectangle(28, 10, 56, 67);
        roiManager("Add");
        makeRectangle(139, 12, 56, 67);
        roiManager("Add");
        setResult("Label", nResults, "Before1");
        setResult("Area", nResults - 1, 15);
        setResult("Label", nResults, "Before2");
        setResult("Area", nResults - 1, 25);
        updateResults();
        waitForUser("Measure before");
        roiManager("measure");
        waitForUser("Measure after");
        setResult("Label", nResults, "After1");
        setResult("Area", nResults - 1, 35);
        setResult("Label", nResults, "After2");
        setResult("Area" , nResults - 1, 45);
        updateResults();
        roiManager("measure");
Is this an expected behavior or a bug (i.e. that the results window content 
gets resetted upon the first measurement made)?
Kindest regards,
Philippe 

Philippe CARL 
Laboratoire de Bioimagerie et Pathologies 
UMR 7021 CNRS - Université de Strasbourg 
Faculté de Pharmacie 
74 route du Rhin 
67401 ILLKIRCH 
Tel : +33(0)3 68 85 41 41

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html