Sra. Morillas,

   For airborne image sensors we use a metric called relative edge response 
(RER) which is derived from the edge spread response (ESF). Satellite image 
sensors also use this concept.

   We use RER both to focus a sensor in flight and to evaluate its performance. 
I'm interested in finding out more about COQ and trying it out.

   Are you analyzing horizontal and vertical edges to focus a sensor, measure 
performance or both?

   Thanks.

Jeff Stokes
Solid State Physicist
San Diego, CA   USA

-----Original Message-----
From: M Dolores Morillas Perez <[email protected]> 
Sent: Thursday, June 26, 2025 3:11 AM
To: [email protected]
Subject: Problems with MTF Calculation

Hello. 

I am a new user of image J 

I have problem with MTF calculation with plugin COQ. 

When I have analized an horizontal edge with plugin COQ, the values of MTF (Y 
AXIS) is NaN 

Could you help me? 

Kind Regards, 

Mª Dolores Morillas 

Medical Phisicist 

H.U.V.V 

Málaga

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html

Reply via email to