Sorry wrong list.
On Aug 8, 2013, at 8:16 AM, Bradley Lowekamp <[email protected]> wrote:
> Hello,
>
> We are experiencing a rather critical bug, that is changing our Origin, when
> viewing the "Volume Information" in the Volumes module. This is on yesterdays
> nightly. I don't know when it started to occur, as we are starting to look at
> some older dataset which were previously segmented.
>
> This sounded similar to some issues mentioned during the TCON related to the
> double spin boxes or precision preferences.
>
> Initially:
>
>>>> lm1 = sitkUtils.PullFromSlicer("A Close")
>>>> print lm1
>
> Image (0x13b2ca030)
> RTTI typeinfo: itk::Image<unsigned short, 3u>
> Reference Count: 1
> Modified Time: 3771
> Debug: Off
> Observers:
> none
> Source: (none)
> Source output name: (none)
> Release Data: Off
> Data Released: False
> Global Release Data: Off
> PipelineMTime: 3597
> UpdateMTime: 3770
> RealTimeStamp: 0 seconds
> LargestPossibleRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> BufferedRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> RequestedRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> Spacing: [160, 160, 480]
> Origin: [547339, 218860, 20904.4]
> Direction:
> -1 0 0
> 0 -1 0
> 0 0 1
>
> After viewing in Volumes module:
>>>> lm1 = sitkUtils.PullFromSlicer("A Close")
>>>> print lm1
> Image (0x13b222ad0)
> RTTI typeinfo: itk::Image<unsigned short, 3u>
> Reference Count: 1
> Modified Time: 4481
> Debug: Off
> Observers:
> none
> Source: (none)
> Source output name: (none)
> Release Data: Off
> Data Released: False
> Global Release Data: Off
> PipelineMTime: 4307
> UpdateMTime: 4480
> RealTimeStamp: 0 seconds
> LargestPossibleRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> BufferedRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> RequestedRegion:
> Dimension: 3
> Index: [0, 0, 0]
> Size: [2618, 1368, 325]
> Spacing: [160, 160, 480]
> Origin: [10000, 10000, 10000]
> Direction:
> -1 0 0
> 0 -1 0
> 0 0 1
>
> Note the change in the origin! We have also observed other odd behaviors such
> as ROI changing, location, but it's hard for me to figure how what has change
> with respect to where in those cases.
>
> This data set is a little odd of us because the user specified the units in
> angstroms and not nano-meters, so everything is 10X bigger than normal.
>
> I will continue to investigate and will write a test which uses synthetic
> data to reproduce the above, hopefully without needed so many pixels.
>
> Thanks,
> Brad
> _______________________________________________
> Powered by www.kitware.com
>
> Visit other Kitware open-source projects at
> http://www.kitware.com/opensource/opensource.html
>
> Kitware offers ITK Training Courses, for more information visit:
> http://kitware.com/products/protraining.php
>
> Please keep messages on-topic and check the ITK FAQ at:
> http://www.itk.org/Wiki/ITK_FAQ
>
> Follow this link to subscribe/unsubscribe:
> http://www.itk.org/mailman/listinfo/insight-developers
_______________________________________________
Powered by www.kitware.com
Visit other Kitware open-source projects at
http://www.kitware.com/opensource/opensource.html